-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen
HomeHome > Products > Evaporation Chamber > -40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen
-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

DWC-40 -40~+30 degree Low Temperature Chamber for Cooling Impact Specimen 1. Application The machine is designed accordi
Basic Info
Model NO. DWC-40
Control Manual Control
Weight 100-500Kg
Power Source AC220V
Cooling Method Compressor Cooling
Transport Package Plywood Exporting Package
Specification 200kg 1.3CMB
Trademark HST
Origin Jinan, Shandong, China
HS Code 9031809090
Production Capacity 1000 Sets/Month
Product Description
DWC-40 -40~+30 degree Low Temperature Chamber for Cooling Impact Specimen

 

1. Application
The machine is designed according to Charpy notch Impact Test Method for Metal Material, and adopts compressor cooling technology. It utilizes the heat balance principle and cycle stirring method to realize the constant temperature cooling to impact specimen with the reliable performance. Digital display, automatic control temperature, and it is the ideal equipment for cooling and keeping temperature to impact specimen.

2. Main component:
The machine obtains one compressor, heating unit, electronic control box , cooling tank, cooling medium circulation system, automatic warning device, etc.

Standards:ASTM, E23-02a, En10045, ISO83,GB/T229-2009

3. Working principle:
Boot refrigeration switch, compressor begin to work, refrigeration system into formal working state. Refrigeration compressor continuous work, when close to the setting temperature, the heating device which is in the cooling bath began to scale with heat. To balance redundant cold quantity produced by the refrigeration system, in order to achieve the purpose of constant temperature. Stirring can make cooling medium of the cooling tank continuously circulation, make the temperature uniform.

4. Features:
4.1Imported compressor, DANFUS valve, imported evaporation-condensation machine;
4.2Controlled by intelligent instrument, digital presentation temperature value, automatic control temperature, automatic time and alarm.
4.3high security, refrigerate fast, large volume

5. Main Specifications:
ModelDWC-40DWC-60DWC-80
DWC-100
Temperature range+30~-40°+30~-60°+30~-80°+30~-100°
Temperature Control Accuracy ±0.5°




Temperature dropping speed
+30°C~0°C
1.2°C/min
+30°C~0°C
2°C/min
+30°C~0°C
2°C/min
+30°C~0°C
2°C/min
0°c~-20°C
0.8°C/min
0°c~-20°C
1.5°C/min
0°c~-20°C
1.5°C/min
0°c~-20°C
1.5°C/min
-20°C~-40°C
0.5°C/min
-20°C~-40°C
1.0°C/min
-20°C~-60°C
1.0°C/min
-20°C~-40°C
1.0°C/min
-40°C~-60°C
0.7°C/min
-60°C~-80°C
0.7°C/min
-60°C~-100°C
0.7°C/min
Cold Room Volume 150×505×240mm
Dimensions 900×505×850 mm900×505×850 mm900×505×850 mm1500×1200×1200 mm
Box MaterialSteel Spray
Loading the number of samples>60>60>60>200
Mode of refrigerationCompressor refrigeration
Cooling MediumEthanol or other unfrozen liquid
Power7Kw7Kw7Kw7Kw

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen

-40~+30 Degree Low Temperature Chamber for Cooling Impact Specimen